Comparison of Nonactive Powers for the Detection of Dominant Harmonic Sources in Power Systems
2008
This paper deals with an innovative technique for the detection of disturbing loads in distorted power systems. The technique is a single-point strategy based on a comparison among different ldquononactiverdquo power quantities already proposed in the literature, which are measured at the same metering section. In this paper, the effectiveness of the strategy is discussed, which also considered the errors of the measurement transducers; the analysis is supported by simulation tests, which were carried out on both a simple single-phase system and an IEEE standard three-phase test power system. The latter was used by other authors as a benchmark system for the analysis of multipoint measureme…
Current transformers effects on the measurement of harmonic active power in LV and MV networks
2011
The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …
Characterization and Error Compensation of a Rogowski Coil in the Presence of Harmonics
2011
This paper reports the results of an experimental study dealing with a commercial Rogowski coil current transducer (RCCT) in the presence of harmonic distortion. The RCCT was observed under two conditions: 1) sinusoidal excitation with frequencies from 50 to 750 Hz and 2) nonsinusoidal excitation using fundamental frequency and one harmonic, with adjustable amplitude and phase shift. The experimental results show only a weak dependence of the harmonic current ratio error and phase displacement on the amplitude and phase shift of the excitation harmonic. The phase displacement is also independent of the conductor position within the Rogowski coil window. An error compensation method, based o…
Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion
2010
The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…
Characterization of clamp-on current transformers under nonsinusoidal conditions
2009
This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers
2007
This paper presents an innovative technique for the detection of disturbing loads in distorted power systems. It is a single-point strategy, based on a comparison among different "nonactive" power quantities already proposed in literature, that are measured at the same metering section. In the paper, the results obtained with the application of the proposed technique are compared with those of other techniques for the monitoring of the harmonic pollution, both single-point and multi-point. Moreover, the effectiveness of the strategy is discussed, considering also the errors of the measurement transducers.
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
A set of indicators for arc faults detection based on low frequency harmonic analysis
2016
In this paper a novel set of indicators is presented for arc faults detection in electrical circuits. The indicators are defined starting from an experimental characterization of the arc fault phenomenon and the study of the arcing current in several test conditions, which were chosen in accordance with the UL 1699 Standard requirements. The proposed parameters are measured by means of a high resolution low frequency spectral analysis of the arcing current, which allows to achieve a good spectral resolution even with short observation windows.
A self-synchronizing instrument for harmonic sources detection in power systems
2004
The deregulation of energy markets holds out new prospects for contract between customers and utilities, in which the price of energy can depend on voltage quality and load characteristics, as well as on the responsibility for disturbances caused to supply voltage in power systems. In this context, harmonic sources detection is one of the main problems, because of equipment sensibility and the proliferation of loads which absorb non-sinusoidal currents. In this paper the authors present a new instrument based on a time domain method for the detection of harmonic active powers in three-phase systems, which can be usefully applied even in the presence of unbalance or asymmetry. The amplitude …